{"product_id":"1080m-hr-gamma-fan-roof-mounted-vertical-discharge-series","title":"1080m³\/hr  Gamma Fan Roof Mounted Vertical Discharge Series","description":"\u003cp\u003eThe Gamma Series of centrifugal roof units has been designed for use in commercial ducted exhaust applications. These compact and low profile units are fitted with birdmesh to prevent the entry of birds and vermin into the ducting or building.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"RangeRow\"\u003e\n\u003cul\u003e\n\u003cli\u003eRobust, lightweight construction.\u003c\/li\u003e\n\u003cli\u003eChoice of speeds available.\u003c\/li\u003e\n\u003cli\u003eCompact, low profile design.\u003c\/li\u003e\n\u003cli\u003eDesigned for vertical exhaust applications.\u003c\/li\u003e\n\u003cli\u003eTwin vertical discharge fan also available. Provides 100% standby capacity.\u003c\/li\u003e\n\u003cli\u003eShutters are standard on twin fan units and an optional extra for single fan units.\u003c\/li\u003e\n\u003cli\u003eThe pressure loss across the shutter has to be added to the system pressure before making selections.\u003c\/li\u003e\n\u003cli\u003eCan be mounted at angle up to 30°.\u003c\/li\u003e\n\u003cli\u003eMost 3-phase motors are 2-speed star\/delta design.\u003c\/li\u003e\n\u003cli\u003eSupply air units can be supplied.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"RangeRow\"\u003e\n\u003cstrong\u003e\u003cspan class=\"SectionTitleSub\"\u003eConstruction:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eCowls are UV-stabilised plastic.\u003c\/li\u003e\n\u003cli\u003eImpellers are backward-curved centrifugal design and can be plastic, steel or aluminium.\u003c\/li\u003e\n\u003cli\u003eSteel components have a corrosion resistant finish.\u003c\/li\u003e\n\u003cli\u003eBird-mesh guards are fitted as standard to both downflow and vertical exhaust models.\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"SectionTitleSub\"\u003eMotors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eType - external rotor, squirrel cage induction motor\u003c\/li\u003e\n\u003cli\u003eElectricity supply - 230V, single and 415V, three-phase, 50Hz\u003c\/li\u003e\n\u003cli\u003eBearings - sealed-for-life, ball\u003c\/li\u003e\n\u003cli\u003eSpeed-controllable using electronic or auto-transformer controllers (except CE316)\u003c\/li\u003e\n\u003cli\u003eMost three-phase units are fitted with 2-speed star\/delta design motors\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"SectionTitleSub\"\u003eInternal Thermal Protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eThermal protection is supplied as standard on all motors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cstrong\u003eTesting\u003c\/strong\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eAir flow tests to ISO5801:2007\u003c\/li\u003e\n\u003cli\u003eNoise tests to BS848:Part 2, 1985\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cb\u003eSuggested Specifications:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eThe Gamma Series of centrifugal roof ventilators shall be of the vertical exhaust type as designed and manufactured by Fantech Pty. Ltd.\u003c\/li\u003e\n\u003cli\u003eImpellers shall be backward-curved centrifugal design and driven by speed-controllable external rotor motors with integral thermal protection.\u003c\/li\u003e\n\u003cli\u003eThe windband shall be of the vertical exhaust design and formed from plastic. Steel components shall be corrosion protected.\u003c\/li\u003e\n\u003cli\u003eAll models shall be fully tested as a complete assembled unit to ISO5801:2007 for air flow and BS848:Part 2, 1985 for noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eTechnical Data - CE284V\u003c\/strong\u003e\n\u003cdiv\u003e\n\u003ctable width=\"100%\" class=\"Table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpeed [rps]\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAvg. dBA @ 3m\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ekWatts (Input)\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eAmps\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax.°C\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eApprox. Weight [kg]\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e0.09\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSound Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"Table\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eType\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e63\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e125\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e250\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e500\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e1K\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e2K\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e4K\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e8K\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd scope=\"col\"\u003eInlet\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eDimensions\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"ImageDimension\"\u003e\u003cimg src=\"https:\/\/www.fantech.com.au\/images\/\/dimension\/gammav_dwg.gif\" class=\"imgDim\"\u003e\u003c\/div\u003e\n\u003ctable class=\"dataTable\" summary=\"Dimension Data\" id=\"background-image-Table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eA\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eB\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eC\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eD\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eE\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eF\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eG\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e575\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e*All dimensions in mm, unless otherwise stated\u003c\/p\u003e\n\u003cstrong\u003eWiring Diagram\u003c\/strong\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cimg src=\"https:\/\/www.fantech.com.au\/images\/\/wirediag\/wire_1ph_diag06.gif\"\u003e\u003cbr\u003e\n\u003cp\u003eDiagram shown is for single-speed only.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e","brand":"Fantech","offers":[{"title":"Default Title","offer_id":46116045029602,"sku":"FANCE284V","price":1222.2,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/3595\/4146\/files\/1080m3hr-Gamma-Fan-Roof-Mounted-Vertical-Discharge-Series-Roof-Mounted-Fans-FANCE284V-The-Lighting-Outlet_product-view.jpg?v=1775704635","url":"https:\/\/thelightingoutlet.co.nz\/products\/1080m-hr-gamma-fan-roof-mounted-vertical-discharge-series","provider":"The Lighting Outlet","version":"1.0","type":"link"}